Burner Heads and Nebulizers for Atomic Absorption原子吸收燃烧头和雾化器
- Nebulizer type
- concentric, V-groove or inert
- Sample uptake rate
- 4–6 mL/min
测汞仪

Photo for reference; configuration may vary by order.
Model No. MEA-0005 · Atomic Absorption Spectrometers
连续汞排放监测系统
Incinerators, coal-fired plants, cement kilns and smelters subject to mercury limits need continuous stack data. This system keeps its sample line at 120–180 °C, detects 0.1–1 µg/m3 with a 60–180 s response and calibrates against a gas-phase mercury generator. Outputs include 4–20 mA, Modbus and Ethernet in an outdoor-rated cabinet. Send stack conditions for a proposal.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Incinerators, coal-fired plants, cement kilns and smelters subject to mercury limits need continuous stack data. This system keeps its sample line at 120–180 °C, detects 0.1–1 µg/m3 with a 60–180 s response and calibrates against a gas-phase mercury generator. Outputs include 4–20 mA, Modbus and Ethernet in an outdoor-rated cabinet. Send stack conditions for a proposal.
| Parameter | Value |
|---|---|
| Measurement range 测量范围 | 0–100 µg/m3 or higher |
| Detection limit 检出限 | 0.1–1 µg/m3 |
| Response time 响应时间 | 60–180 s |
| Sample line temperature 采样管温度 | 120–180 °C |
| Detection principle 检测原理 | Zeeman AAS, UV or amalgamation |
| Calibration 校准 | gas-phase mercury generator |
| Data output 数据输出 | 4–20 mA, Modbus, Ethernet |
| Enclosure 外壳 | industrial cabinet, outdoor rated |
| Zero and span check 零点和量程检查 | automatic, programmable |
| Operating temperature 工作温度 | -10 to 50 °C |
| Model No. | MEA-0005 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.