Model No. BOA-0004 · Water Testing Equipment

Dissolved-Oxygen BOD Measurement System

溶解氧法 BOD 测定系统

Referee labs and method-validation work still rely on the classic route: dilute, measure oxygen, incubate, measure again. This system uses standard 300 mL bottles, a 20 °C incubator and a membrane or luminescent probe resolving 0.01 mg/L. Five-day tests are standard, with 7 or 10 days optional. It also makes a solid training setup.

Method
Dilution with dissolved oxygen measurement
Bottle volume
300 mL standard
Incubation temperature
20 °C, ±1 °C
Test duration
5 days standard, 7 or 10 optional
Oxygen range
0–20 mg/L
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Referee labs and method-validation work still rely on the classic route: dilute, measure oxygen, incubate, measure again. This system uses standard 300 mL bottles, a 20 °C incubator and a membrane or luminescent probe resolving 0.01 mg/L. Five-day tests are standard, with 7 or 10 days optional. It also makes a solid training setup.

Highlights

  • Follows the reference dilution approach for referee BOD5 results
  • Choice of membrane or luminescent optical oxygen sensor
  • 0.01 mg/L resolution and ±0.2 mg/L oxygen accuracy
  • 5-day standard tests, with 7- or 10-day options

Applications

  • Regulatory BOD5 determinations
  • Referee analysis and method validation
  • Municipal and industrial effluent testing
  • Laboratory training in BOD methodology

Specifications 技术参数

ParameterValue
Method 方法 Dilution with dissolved oxygen measurement
Bottle volume 瓶体积 300 mL standard
Incubation temperature 培养温度 20 °C, ±1 °C
Test duration 测试时长 5 days standard, 7 or 10 optional
Oxygen range 氧范围 0–20 mg/L
Oxygen resolution 氧分辨率 0.01 mg/L
Oxygen accuracy 氧准确度 ±0.2 mg/L
Sensor type 传感器类型 Membrane or luminescent optical
Acceptance criteria 接受判据 ≥ 2 mg/L remaining and ≥ 2 mg/L depletion
Reference check 参考核查 Glucose-glutamic acid solution
Model No.BOA-0004
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 5815-1 ISO 5815-2 Standard Methods 5210 B EPA 405.1 ISO/IEC 17025

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Dissolved-Oxygen BOD Measurement System (BOA-0004)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.