Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

细胞分析仪器

Cell Analysis

Model No. CEA-0002 · Life Science Equipment

Fluorescence Cell Counter and Viability Analyzer

荧光细胞计数与活率分析仪

PBMCs, bone marrow and debris-heavy primary samples confuse brightfield counting; dual-fluorescence staining fixes that. This analyzer uses AO/PI with blue and green LEDs over two channels, plus trypan blue in brightfield. It counts 5 × 10⁴–3 × 10⁷ cells/mL from 20 μL in about 30 s, sizes 4–60 μm, with CV typically below 6 %.

Counting range
5 × 10⁴–3 × 10⁷ cells/mL
Fluorescence channels
2 (green, red)
Excitation sources
Blue and green LEDs
Sample volume
20 μL
Analysis time
approx. 30 s
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

PBMCs, bone marrow and debris-heavy primary samples confuse brightfield counting; dual-fluorescence staining fixes that. This analyzer uses AO/PI with blue and green LEDs over two channels, plus trypan blue in brightfield. It counts 5 × 10⁴–3 × 10⁷ cells/mL from 20 μL in about 30 s, sizes 4–60 μm, with CV typically below 6 %.

Highlights

  • Counts nucleated cells only, ignoring red cells and debris
  • Suits cell therapy release testing workflows
  • Two methods in one instrument
  • Fast results for isolation QC

Applications

  • PBMC and lymphocyte isolation QC
  • Cell therapy product release testing
  • Bone marrow and whole blood nucleated cell counts
  • Primary cell culture

Specifications 技术参数

ParameterValue
Counting range 计数范围 5 × 10⁴–3 × 10⁷ cells/mL
Fluorescence channels 荧光通道 2 (green, red)
Excitation sources 激发光源 Blue and green LEDs
Sample volume 样品体积 20 μL
Analysis time 分析时间 approx. 30 s
Viability stains 活率染料 AO/PI; trypan blue in brightfield
Cell size range 细胞大小范围 4–60 μm
Precision (CV) 精密度(CV) below 6 % (typical)
Data export 数据导出 USB, LIMS-ready CSV
Power supply 电源 100–240 V, 50/60 Hz
Model No.CEA-0002
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

IEC 61010-1 IEC 61010-2-101 IEC 61326-2-6 IEC 60825-1 ISO 13322-1 ISO 13319

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Fluorescence Cell Counter and Viability Analyzer (CEA-0002)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.