粉体质控单点流动法 BET 比表面积分析仪

Carbon black, silica and filler producers need a surface area number in minutes for batch release. This dynamic flow analyzer uses N₂/He gas and TCD detection, measuring 0.1–2000 m²/g in about 6–10 min per sample on 2–4 stations. Repeatability is within 1.5% RSD. Degassing runs from ambient to 350 °C.

Measurement principle
Dynamic flow, TCD detection
Specific surface area range
0.1–2000 m²/g
Stations
2–4
Gas mixture
N₂/He, 30% N₂ typical
Repeatability
≤ 1.5% RSD
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Carbon black, silica and filler producers need a surface area number in minutes for batch release. This dynamic flow analyzer uses N₂/He gas and TCD detection, measuring 0.1–2000 m²/g in about 6–10 min per sample on 2–4 stations. Repeatability is within 1.5% RSD. Degassing runs from ambient to 350 °C.

Highlights

  • Results in roughly 6–10 min per sample
  • 2–4 stations for parallel QC
  • Repeatability within 1.5% RSD
  • No vacuum pump needed for flow method

Applications

  • Carbon black and silica QC
  • Pigment and filler batch release
  • Catalyst and alumina support checks
  • Battery active material screening
  • Cement additive incoming inspection

Specifications 技术参数

ParameterValue
Measurement principle 测量原理 Dynamic flow, TCD detection
Specific surface area range 比表面积范围 0.1–2000 m²/g
Stations 工位数 2–4
Gas mixture 混合气 N₂/He, 30% N₂ typical
Repeatability 重复性 ≤ 1.5% RSD
Accuracy 准确度 ± 2% vs reference material
Analysis time 分析时间 ≈ 6–10 min per sample
Degassing temperature 脱气温度 Ambient–350 °C
Sample tube 样品管 Glass, 6–9 mm
Sample mass 样品量 0.05–2 g
Model No.SAA-0001
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 9277 ASTM D3663 ASTM C204 EN 196-6 ASTM D6556 ISO 15901-2 GB/T 19587

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Single-Point Flow BET Surface Area Analyzer for Powder QC (SAA-0001)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

5 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.