Heat-Flux Differential Scanning Calorimeter热流型差示扫描量热仪
- Temperature range
- −90–600 °C (cooling dependent)
- Heating rate
- 0.1–100 °C/min
热重分析仪

Photo for reference; configuration may vary by order.
Model No. TGA-0005 · Thermal Analysis Instruments
热重-质谱联用分析仪
Battery outgassing, binder burnout and catalyst studies often involve small molecules that infrared cannot resolve. Pairing a TGA with an electron-ionisation mass spectrometer covers 1–300 amu at a maximum of 10 spectra/s, with detection in the ppm range for many species. The interface is heated to 250 °C. Ask us about isotope-labelled experiments.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Battery outgassing, binder burnout and catalyst studies often involve small molecules that infrared cannot resolve. Pairing a TGA with an electron-ionisation mass spectrometer covers 1–300 amu at a maximum of 10 spectra/s, with detection in the ppm range for many species. The interface is heated to 250 °C. Ask us about isotope-labelled experiments.
| Parameter | Value |
|---|---|
| Temperature range 温度范围 | Ambient–1000 °C (TGA) |
| Balance resolution 天平分辨率 | 0.1 µg |
| Interface temperature 接口温度 | Up to 250 °C |
| Mass range 质量范围 | 1–300 amu |
| Scan rate 扫描速率 | Up to 10 spectra/s |
| Detection limit 检出限 | ppm range for many species |
| Ion source 离子源 | Electron ionisation, 70 eV |
| Heating rate 升温速率 | 0.1–50 °C/min |
| Gas modes 气体模式 | Scan, selected ion monitoring, cycle |
| Data output 数据输出 | Coupled mass and MS data files |
| Model No. | TGA-0005 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.