Automated Chemiluminescence Immunoassay Analyzer全自动化学发光免疫分析仪
- Throughput
- 120–240 tests/h
- First-result time
- 15–30 min
荧光免疫分析仪

Photo for reference; configuration may vary by order.
Model No. FLI-0005 · Immunoassay Analyzers
荧光偏振免疫分析仪
Therapeutic drug monitoring and small-molecule assays suit fluorescence polarization, which needs no separation step. Results take 2–6 min per analyte from 20–100 µL of serum or plasma, with incubation at 30 °C or 37 °C ±0.5 °C. Typical excitation is 480–500 nm, and 10,000 results are kept with calibration history.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Therapeutic drug monitoring and small-molecule assays suit fluorescence polarization, which needs no separation step. Results take 2–6 min per analyte from 20–100 µL of serum or plasma, with incubation at 30 °C or 37 °C ±0.5 °C. Typical excitation is 480–500 nm, and 10,000 results are kept with calibration history.
| Parameter | Value |
|---|---|
| Measurement principle 测量原理 | Fluorescence polarization of a labelled tracer |
| Excitation wavelength 激发波长 | Typically 480–500 nm |
| Emission wavelength 发射波长 | Typically 520–540 nm |
| Sample volume 样本量 | 20–100 µL serum or plasma |
| Time to result 出结果时间 | 2–6 min per analyte |
| Incubation temperature 温育温度 | 30 °C or 37 °C ±0.5 °C |
| Measuring range 测量范围 | Analyte specific, typically 2 to 3 orders of magnitude |
| Data storage 数据存储 | 10,000 results with calibration history |
| Interfaces 接口 | RS-232, USB, LAN with LIS option |
| Model No. | FLI-0005 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.