High-Temperature DSC for Engineering Polymers

工程塑料用高温差示扫描量热仪

Polyimides, composite matrices and inorganic fillers have transitions far above the reach of a standard DSC. This model reaches 1500 °C, optionally 1600 °C, using platinum or platinum-rhodium thermocouples with alumina, platinum or ceramic crucibles. Temperature accuracy is ±2 °C at 1000 °C, with argon or nitrogen purge and an oxygen option.

Temperature range
Ambient to 1500 °C (optional 1600 °C)
Heating rate
0.1–50 °C/min
Temperature accuracy
±2 °C at 1000 °C
Calorimetric accuracy
±3% for metal standards
Sensor type
Platinum or platinum-rhodium thermocouples
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Polyimides, composite matrices and inorganic fillers have transitions far above the reach of a standard DSC. This model reaches 1500 °C, optionally 1600 °C, using platinum or platinum-rhodium thermocouples with alumina, platinum or ceramic crucibles. Temperature accuracy is ±2 °C at 1000 °C, with argon or nitrogen purge and an oxygen option.

Highlights

  • Checks melting of glass, ceramic and fibre fillers before compounding.
  • Calorimetric accuracy of ±3% against metal standards.
  • Accepts 10–50 mg samples for heterogeneous composites.
  • Suitable for thermal stability testing of heat-resistant coatings.

Applications

  • Polyimide and high-performance polymer transitions
  • Composite matrix cure and decomposition studies
  • Melting behaviour of inorganic fillers and fibres
  • Glass and ceramic filler verification
  • Thermal stability of heat-resistant coatings

Specifications 技术参数

ParameterValue
Temperature range 温度范围 Ambient to 1500 °C (optional 1600 °C)
Heating rate 升温速率 0.1–50 °C/min
Temperature accuracy 温度准确度 ±2 °C at 1000 °C
Calorimetric accuracy 量热准确度 ±3% for metal standards
Sensor type 传感器类型 Platinum or platinum-rhodium thermocouples
Sample holder material 样品支架材质 Alumina, platinum or ceramic crucibles
Typical sample mass 典型样品量 10–50 mg
Atmosphere control 气氛控制 Argon or nitrogen purge, oxygen option
Purge gas flow 吹扫气流量 20–100 mL/min
Cooling 冷却方式 Forced air or water cooled furnace
Model No.DSCA-0006
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 11357-1 ISO 11357-2 ISO 11357-3 ASTM D3418 ASTM E1356 ASTM D3895 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: High-Temperature DSC for Engineering Polymers (DSCA-0006)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.