Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

离子分析仪

Ion Analyzers

Model No. IOA-0003 · Water Analysis Equipment

Ion Chromatograph for Cation Analysis in Water

水中阳离子分析用离子色谱仪

Hardness, ammonium and cooling-water chemistry all come down to the same six cations: Li+, Na+, NH4+, K+, Mg2+ and Ca2+. This chromatograph separates them in one run on methanesulfonic acid eluent, with suppressed or non-suppressed conductivity detection. Linearity holds at R² ≥ 0.999 over 0.1–50 mg/L, and detection limits are 5–50 µg/L.

Analytes
Li+, Na+, NH4+, K+, Mg2+, Ca2+
Eluent
Methanesulfonic acid, 20–40 mmol/L
Flow rate
0.5–1.5 mL/min
Injection volume
10–50 µL
Detector
Conductivity (suppressed or non-suppressed)
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Hardness, ammonium and cooling-water chemistry all come down to the same six cations: Li+, Na+, NH4+, K+, Mg2+ and Ca2+. This chromatograph separates them in one run on methanesulfonic acid eluent, with suppressed or non-suppressed conductivity detection. Linearity holds at R² ≥ 0.999 over 0.1–50 mg/L, and detection limits are 5–50 µg/L.

Highlights

  • Six key cations separated in a single run
  • Suppressed or non-suppressed conductivity, per budget and sensitivity
  • Linearity R² ≥ 0.999 across 0.1–50 mg/L
  • Also suits fertilizer and soil extract analysis

Applications

  • Water hardness and ammonium determination
  • Cooling water and boiler chemistry
  • Groundwater and surface water surveys
  • Fertilizer and soil extract analysis

Specifications 技术参数

ParameterValue
Analytes 分析物 Li+, Na+, NH4+, K+, Mg2+, Ca2+
Eluent 淋洗液 Methanesulfonic acid, 20–40 mmol/L
Flow rate 流速 0.5–1.5 mL/min
Injection volume 进样体积 10–50 µL
Detector 检测器 Conductivity (suppressed or non-suppressed)
Column oven 柱温箱 30–40 °C
Detection limit 检出限 5–50 µg/L
Linearity 线性 R² ≥ 0.999 over 0.1–50 mg/L
Typical run time 典型分析时间 12–20 min
Autosampler capacity 自动进样器容量 50–100 vials
Model No.IOA-0003
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 10304-1 ISO 10304-2 EPA Method 300.1 ASTM D4327 ASTM D1179 HJ 84 GB/T 5750.5 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Ion Chromatograph for Cation Analysis in Water (IOA-0003)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.