Labs checking drinking water against GB 5749, or profiling chloride, sulfate and nutrients in wastewater, can determine the common anions in one injection. This chromatograph uses suppressed conductivity detection, a 35 MPa pump and either carbonate/bicarbonate or electrolytically generated KOH eluent. Detection limits for chloride, nitrate and sulfate reach 1–20 µg/L.

Pump pressure limit
35 MPa (5000 psi)
Flow rate range
0.2–2.0 mL/min
Eluent
Carbonate/bicarbonate or KOH (electrolytic)
Injection volume
10–100 µL
Detector
Suppressed conductivity, 0–15,000 µS/cm
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Labs checking drinking water against GB 5749, or profiling chloride, sulfate and nutrients in wastewater, can determine the common anions in one injection. This chromatograph uses suppressed conductivity detection, a 35 MPa pump and either carbonate/bicarbonate or electrolytically generated KOH eluent. Detection limits for chloride, nitrate and sulfate reach 1–20 µg/L.

Highlights

  • Common anions resolved in a single injection
  • Carbonate/bicarbonate or electrolytic KOH eluent options
  • 1–20 µg/L detection limits for Cl−, NO3− and SO42−
  • Retention time RSD ≤ 1% for confident peak identification

Applications

  • Drinking water anion compliance under GB 5749
  • Groundwater and surface water surveys
  • Wastewater chloride, sulfate and nutrient profiling
  • Condensate and boiler water analysis

Specifications 技术参数

ParameterValue
Pump pressure limit 泵压上限 35 MPa (5000 psi)
Flow rate range 流速范围 0.2–2.0 mL/min
Eluent 淋洗液 Carbonate/bicarbonate or KOH (electrolytic)
Injection volume 进样体积 10–100 µL
Detector 检测器 Suppressed conductivity, 0–15,000 µS/cm
Column oven temperature 柱温范围 Ambient +5 to 60 °C
Detection limit (Cl−, NO3−, SO42−) 检出限(Cl−、NO3−、SO42−) 1–20 µg/L
Retention time RSD 保留时间 RSD ≤ 1%
Typical run time 典型分析时间 15–25 min
Autosampler capacity 自动进样器容量 50–100 vials
Model No.IOA-0002
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 10304-1 ISO 10304-2 EPA Method 300.1 ASTM D4327 ASTM D1179 HJ 84 GB/T 5750.5 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Suppressed-Conductivity Ion Chromatograph for Anion Analysis in Water (IOA-0002)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.