Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

聚合物分析用差示扫描量热仪

DSC

Model No. DSCA-0005 · Polymer Analysis Equipment

Simultaneous DSC-TGA Analyzer for Polymer Analysis

聚合物分析用同步 DSC-TGA 分析仪

Measuring mass loss and heat flow on the same specimen tells you whether an endotherm is melting or evaporation. This simultaneous analyser runs from ambient to 1500 °C with 0.1 µg balance resolution and ±0.5% weighing accuracy. Atmospheres include inert gas, oxygen and humidified nitrogen, with 70–150 µL crucibles for 5–20 mg samples.

Temperature range
Ambient to 1500 °C
Heating rate
0.1–50 °C/min
Balance resolution
0.1 µg
Weighing accuracy
±0.5%
Typical sample mass
5–20 mg
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Measuring mass loss and heat flow on the same specimen tells you whether an endotherm is melting or evaporation. This simultaneous analyser runs from ambient to 1500 °C with 0.1 µg balance resolution and ±0.5% weighing accuracy. Atmospheres include inert gas, oxygen and humidified nitrogen, with 70–150 µL crucibles for 5–20 mg samples.

Highlights

  • One run gives filler content, moisture and decomposition onset.
  • Humidified nitrogen option for moisture-sensitive materials.
  • Calorimetric accuracy of ±2% on indium.
  • Heating rates from 0.1 to 50 °C/min.

Applications

  • Thermoset cure studies with volatile release
  • Filler and carbon black content determination
  • Decomposition onset of flame-retarded polymers
  • Moisture and solvent content of compounds
  • Thermal stability comparison of grades

Specifications 技术参数

ParameterValue
Temperature range 温度范围 Ambient to 1500 °C
Heating rate 升温速率 0.1–50 °C/min
Balance resolution 天平分辨率 0.1 µg
Weighing accuracy 称量准确度 ±0.5%
Typical sample mass 典型样品量 5–20 mg
Calorimetric accuracy 量热准确度 ±2% (indium)
Atmosphere control 气氛控制 Inert, oxygen, humidified nitrogen
Crucible volume 坩埚容积 70–150 µL
Purge gas flow 吹扫气流量 20–100 mL/min
Power supply 电源 220 V, 50/60 Hz
Model No.DSCA-0005
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 11357-1 ISO 11357-2 ISO 11357-3 ASTM D3418 ASTM E1356 ASTM D3895 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Simultaneous DSC-TGA Analyzer for Polymer Analysis (DSCA-0005)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.