Ion Chromatograph for Cation Analysis in Water水中阳离子分析用离子色谱仪
- Analytes
- Li+, Na+, NH4+, K+, Mg2+, Ca2+
- Eluent
- Methanesulfonic acid, 20–40 mmol/L
水质 TOC 分析仪

Photo for reference; configuration may vary by order.
Model No. TOC-0002 · Water Analysis Equipment
饮用水用紫外过硫酸盐 TOC 分析仪
Drinking water labs tracking disinfection by-product precursors work at low carbon levels, where UV-persulfate oxidation shines. This analyzer covers 0.05–50 mg/L TOC with a detection limit of 50 µg/L or better, using 185/254 nm UV and NDIR detection. A 40-vial autosampler lets the lab load a day's samples and walk away.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Drinking water labs tracking disinfection by-product precursors work at low carbon levels, where UV-persulfate oxidation shines. This analyzer covers 0.05–50 mg/L TOC with a detection limit of 50 µg/L or better, using 185/254 nm UV and NDIR detection. A 40-vial autosampler lets the lab load a day's samples and walk away.
| Parameter | Value |
|---|---|
| Oxidation method 氧化方式 | UV (185/254 nm) with sodium persulfate |
| Measuring range (TOC) 测量范围(TOC) | 0.05–50 mg/L |
| Detector 检测器 | NDIR CO2 detector |
| Detection limit 检出限 | ≤ 50 µg/L |
| Repeatability 重复性 | CV ≤ 2% |
| Analysis time 分析时间 | 4–6 min per sample |
| Sample volume 样品体积 | 10–25 mL per analysis |
| Autosampler capacity 自动进样器容量 | 40 vials |
| Carrier gas 载气 | High-purity O2 or N2, 100 mL/min |
| Power supply 电源 | AC 220 V, 50/60 Hz, 300 VA |
| Model No. | TOC-0002 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.