FTIR Gas Analyzer with Heated Multipass Cell带加热多次反射池的 FTIR 气体分析仪
- Spectral range
- 4500–900 cm-1
- Resolution
- 0.5–2 cm-1 selectable
紫外可见光谱仪

Photo for reference; configuration may vary by order.
Model No. UVV-0004 · Spectroscopy Instruments
带帕尔贴多池动力学系统的紫外可见分光光度计
Enzyme labs, biophysics groups and stability teams running temperature-dependent experiments can load 6 or 12 cells and leave the instrument to work. The Peltier changer spans 4–100 °C with ±0.1 °C accuracy, ramps at 0.1–10 °C/min and stirs at up to 1500 rpm. Melting curves, Michaelis–Menten studies and degradation kinetics are typical uses. Specify cell count when quoting.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Enzyme labs, biophysics groups and stability teams running temperature-dependent experiments can load 6 or 12 cells and leave the instrument to work. The Peltier changer spans 4–100 °C with ±0.1 °C accuracy, ramps at 0.1–10 °C/min and stirs at up to 1500 rpm. Melting curves, Michaelis–Menten studies and degradation kinetics are typical uses. Specify cell count when quoting.
| Parameter | Value |
|---|---|
| Wavelength range 波长范围 | 190–1100 nm |
| Spectral bandwidth 光谱带宽 | 1 nm (fixed) or 0.5–4 nm variable |
| Cell positions 样品池位置数 | 6 or 12 |
| Temperature range 温度范围 | 4–100 °C |
| Temperature accuracy 温度准确度 | ±0.1 °C |
| Heating ramp rate 升温速率 | 0.1–10 °C/min |
| Stirring speed 搅拌速度 | Up to 1500 rpm |
| Photometric range 光度范围 | −4 to 4 A |
| Cuvette path length 比色皿光程 | 10 mm (standard) |
| Purge gas 吹扫气体 | Dry nitrogen or air, 1–2 L/min |
| Model No. | UVV-0004 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.