Gas Chromatograph for Dissolved Gas Analysis in Transformer Oil

变压器油溶解气体分析气相色谱仪

Utilities, transformer factories and DGA service labs use this chromatograph to catch overheating, arcing and partial discharge early. TCD and FID with methanizer quantify H2, O2, N2, CH4, CO, CO2, C2H4, C2H6 and C2H2 from about 20–50 mL of oil. Hydrogen detection reaches 5 ppm and hydrocarbons 1 ppm; specify headspace or vacuum extraction.

Gases measured
H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2
Detectors
TCD and FID with methanizer
Detection limit, hydrogen
≤ 5 ppm (v/v in oil)
Detection limit, hydrocarbons
≤ 1 ppm (v/v in oil)
Oil sample volume
≈ 20–50 mL
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Utilities, transformer factories and DGA service labs use this chromatograph to catch overheating, arcing and partial discharge early. TCD and FID with methanizer quantify H2, O2, N2, CH4, CO, CO2, C2H4, C2H6 and C2H2 from about 20–50 mL of oil. Hydrogen detection reaches 5 ppm and hydrocarbons 1 ppm; specify headspace or vacuum extraction.

Highlights

  • Nine fault and atmospheric gases from one oil sample
  • Hydrogen down to 5 ppm and hydrocarbons to 1 ppm
  • Automated headspace or vacuum extraction options
  • About 12–20 min per sample with RSD of 3 % or better

Applications

  • Utility laboratory fault monitoring
  • Transformer manufacturer factory tests
  • Independent DGA service laboratories

Specifications 技术参数

ParameterValue
Gases measured 测定气体 H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2
Detectors 检测器 TCD and FID with methanizer
Detection limit, hydrogen 检出限(氢气) ≤ 5 ppm (v/v in oil)
Detection limit, hydrocarbons 检出限(烃类) ≤ 1 ppm (v/v in oil)
Oil sample volume 油样体积 ≈ 20–50 mL
Extraction method 萃取方式 Automated headspace or vacuum
Analysis time 分析时间 ≈ 12–20 min per sample
Repeatability (RSD) 重复性(RSD) ≤ 3 %
Oven temperature range 柱温箱温度范围 Ambient +5 to 400 °C
Model No.TOT-0002
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

IEC 60156 ASTM D1816 ASTM D877 IEC 60599 ASTM D3612 IEC 60814 IEC 60247 ASTM D971 GB/T 507

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Gas Chromatograph for Dissolved Gas Analysis in Transformer Oil (TOT-0002)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.