Electronic Densimeter for Plastics塑料电子密度计
- Density resolution
- 0.001 g/cm³
- Density accuracy
- ±0.0005 g/cm³ typical
塑料热分析仪

Photo for reference; configuration may vary by order.
Model No. THA-0005 · Plastic Analysis Equipment
热变形与维卡软化温度测定仪
HDT and Vicat values appear on almost every engineering plastics datasheet, and buyers verifying them need 3 to 6 specimens running at once. This tester heats a bath to 300 °C at 50 or 120 °C/h, applies 0.45 or 1.80 MPa for HDT and 10 or 50 N for Vicat.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
HDT and Vicat values appear on almost every engineering plastics datasheet, and buyers verifying them need 3 to 6 specimens running at once. This tester heats a bath to 300 °C at 50 or 120 °C/h, applies 0.45 or 1.80 MPa for HDT and 10 or 50 N for Vicat.
| Parameter | Value |
|---|---|
| Temperature range 温度范围 | Ambient to 300 °C |
| Heating rates 升温速率 | 50 ± 5 °C/h and 120 ± 10 °C/h |
| Heat deflection loads 热变形负荷 | 0.45 MPa and 1.80 MPa |
| Deflection limit 挠度限值 | 0.32 mm (edgewise) per ISO 75 |
| Vicat needle area 维卡压头面积 | 1 mm², flat ended |
| Vicat loads 维卡负荷 | 10 N and 50 N |
| Penetration limit 压入限值 | 1 mm |
| Simultaneous positions 同时测试位数 | 3–6 |
| Bath medium 浴液介质 | Silicone oil |
| Power supply 电源 | 220 V, 50/60 Hz |
| Model No. | THA-0005 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.