Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

X 射线粉末衍射仪

XRD

Model No. XRD-0003 · X-Ray Analysis Instruments

In-Situ X-Ray Diffractometer with Temperature Stage

带温度台的原位 X 射线衍射仪

Catalysts, battery electrodes and cement change phase under heat, gas or humidity, and this instrument watches it happen. The stage spans -190 to 1600 °C at 0.1–100 °C/min under air, inert, vacuum or reactive gas, with optional 5–95% RH humidity control. A fast position-sensitive detector scans in 10 s to 5 min. Specify temperature and atmosphere needs.

Temperature range
-190 to 1600 °C
Heating rate
0.1–100 °C/min
Atmospheres
air, inert, vacuum, reactive gas
2-theta range
5–120° typical
Detector
position-sensitive, fast
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Catalysts, battery electrodes and cement change phase under heat, gas or humidity, and this instrument watches it happen. The stage spans -190 to 1600 °C at 0.1–100 °C/min under air, inert, vacuum or reactive gas, with optional 5–95% RH humidity control. A fast position-sensitive detector scans in 10 s to 5 min. Specify temperature and atmosphere needs.

Highlights

  • Wide temperature span from cryogenic to 1600 °C
  • Reactive gas and humidity options for real conditions
  • Fast scans capture transient phases
  • Beryllium or kapton windows to suit conditions

Applications

  • Catalyst phase evolution during reaction
  • Battery electrode cycling studies
  • Cement hydration and dehydration
  • Metal oxidation and sintering behavior

Specifications 技术参数

ParameterValue
Temperature range 温度范围 -190 to 1600 °C
Heating rate 升温速率 0.1–100 °C/min
Atmospheres 气氛 air, inert, vacuum, reactive gas
2-theta range 2-theta 范围 5–120° typical
Detector 检测器 position-sensitive, fast
Scan time 扫描时间 10 s to 5 min
Humidity control 湿度控制 optional 5–95% RH
Window material 窗口材料 beryllium or kapton
Temperature accuracy 温度准确度 ±1 °C with calibration
Interface 通信接口 Ethernet
Model No.XRD-0003
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

USP <941> X-Ray Diffraction ASTM E915 Verifying the alignment of X-ray diffraction instrumentation ASTM D934 Identification of crystalline compounds in water-formed deposits ISO 20203 Carbonaceous materials for aluminium production — XRD of calcined coke ISO/IEC 17025 IEC 61010-2-091

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: In-Situ X-Ray Diffractometer with Temperature Stage (XRD-0003)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.