Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

飞行时间质谱仪

TOF-MS

Model No. TOM-0003 · Mass Spectrometry Instruments

MALDI-TOF/TOF Tandem Mass Spectrometer

MALDI-TOF/TOF 串联质谱仪

Proteomics groups sequencing peptides and mapping phosphorylation or glycosylation need MS/MS on MALDI spots. This TOF/TOF selects precursors from m/z 700–4000 in a 1–3 u window, gives fragment resolution of about 1500 FWHM and fragment accuracy of ≤50 ppm. MS resolution is at least 15000 FWHM. Sensitivity reaches ≤50 fmol for Glu-fibrinopeptide in MS/MS.

MS mass range
m/z 500–30000 (reflectron)
MS/MS precursor range
m/z 700–4000
MS resolution (m/z 2500)
≥ 15000 FWHM
MS/MS resolution
≥ 1500 FWHM (typical)
Precursor selection window
~1–3 u
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Proteomics groups sequencing peptides and mapping phosphorylation or glycosylation need MS/MS on MALDI spots. This TOF/TOF selects precursors from m/z 700–4000 in a 1–3 u window, gives fragment resolution of about 1500 FWHM and fragment accuracy of ≤50 ppm. MS resolution is at least 15000 FWHM. Sensitivity reaches ≤50 fmol for Glu-fibrinopeptide in MS/MS.

Highlights

  • Tandem TOF for sequence information from spots
  • Re-analyse stored target plates later
  • Site mapping for modifications
  • Confirms bacterial biomarkers and toxins

Applications

  • Peptide sequencing and protein identification
  • Phosphorylation and glycosylation site mapping
  • Structural confirmation of synthetic polymers
  • Oligosaccharide and glycan analysis
  • Bacterial biomarker and toxin confirmation

Specifications 技术参数

ParameterValue
MS mass range MS 质量范围 m/z 500–30000 (reflectron)
MS/MS precursor range MS/MS 母离子范围 m/z 700–4000
MS resolution (m/z 2500) MS 分辨率(m/z 2500) ≥ 15000 FWHM
MS/MS resolution MS/MS 分辨率 ≥ 1500 FWHM (typical)
Precursor selection window 母离子选择窗口 ~1–3 u
Mass accuracy, MS (internal) 质量准确度,MS(内标) ≤ 5 ppm
Mass accuracy, MS/MS fragments 质量准确度,MS/MS 碎片 ≤ 50 ppm
MS/MS sensitivity (Glu-fibrinopeptide) MS/MS 灵敏度(Glu-纤维蛋白肽) ≤ 50 fmol on target
Laser repetition rate 激光重复频率 up to 2 kHz
Collision gas 碰撞气 Helium or air, 1–2 keV collision energy
Model No.TOM-0003
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ASTM D7134 ISO 11260 ISO/TS 16940 USP <1052> Biotechnology-Derived Articles ASTM E2933 ISO 15189 ISO/IEC 17025 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: MALDI-TOF/TOF Tandem Mass Spectrometer (TOM-0003)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.