Model No. TOM-0005 · Mass Spectrometry Instruments

Multi-Reflecting TOF High-Resolution Mass Spectrometer

多反射飞行时间高分辨质谱仪

Petroleomics, natural organic matter and isotopic fine structure demand resolving power beyond a standard TOF. This multi-reflecting TOF folds an effective 30–100 m flight path to reach 50000–100000 FWHM at m/z 200 and mass accuracy under 1 ppm with internal calibration. ESI, APCI and APPI sources are standard, EI optional. Discuss your research goals with us.

Mass range
m/z 50–2000 (typical)
Resolving power
50000–100000 FWHM (m/z 200)
Mass accuracy (internal calibration)
< 1 ppm RMS
Mass accuracy (external calibration)
< 3 ppm
Effective flight path
~30–100 m
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Petroleomics, natural organic matter and isotopic fine structure demand resolving power beyond a standard TOF. This multi-reflecting TOF folds an effective 30–100 m flight path to reach 50000–100000 FWHM at m/z 200 and mass accuracy under 1 ppm with internal calibration. ESI, APCI and APPI sources are standard, EI optional. Discuss your research goals with us.

Highlights

  • Very high resolving power for complex mixtures
  • Sub-ppm accuracy for confident formula assignment
  • Multiple ionisation sources
  • Suitable for isotopic fine-structure studies

Applications

  • Petroleomics and crude oil characterization
  • Natural organic matter analysis
  • Non-targeted metabolomics and lipidomics
  • Forensic and doping screening
  • Isotopic fine-structure studies

Specifications 技术参数

ParameterValue
Mass range 质量范围 m/z 50–2000 (typical)
Resolving power 分辨率 50000–100000 FWHM (m/z 200)
Mass accuracy (internal calibration) 质量准确度(内标校准) < 1 ppm RMS
Mass accuracy (external calibration) 质量准确度(外标校准) < 3 ppm
Effective flight path 有效飞行路径 ~30–100 m
Acquisition rate 采集速率 1–10 Hz at full resolution (typical)
Dynamic range 动态范围 ~10^3–10^4
Ion sources 离子源 ESI, APCI, APPI; optional EI
Polarity switching 极性切换 ≤ 1 s
Vacuum system 真空系统 Turbomolecular, analyzer ≤ 10^-7 mbar
Model No.TOM-0005
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ASTM D7134 ISO 11260 ISO/TS 16940 USP <1052> Biotechnology-Derived Articles ASTM E2933 ISO 15189 ISO/IEC 17025 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Multi-Reflecting TOF High-Resolution Mass Spectrometer (TOM-0005)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.