Exporters screening plastic parts for restricted substances and brominated flame retardants need a fast, non-destructive answer. This XRF covers Na to U, with light elements in vacuum, using a 25–50 mm² silicon drift detector. Detection limits are 1–50 ppm depending on element, with 60–300 s per sample.

Element range
Na to U (light elements in vacuum)
Detector
Silicon drift detector, 25–50 mm²
Energy resolution
About 130–150 eV at Mn Kα
Tube voltage
Up to 50 kV
Measurement spot
1–10 mm selectable
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Exporters screening plastic parts for restricted substances and brominated flame retardants need a fast, non-destructive answer. This XRF covers Na to U, with light elements in vacuum, using a 25–50 mm² silicon drift detector. Detection limits are 1–50 ppm depending on element, with 60–300 s per sample.

Highlights

  • Selectable 1–10 mm spot for small parts.
  • Air, helium or vacuum atmosphere.
  • Energy resolution about 130–150 eV at Mn Kα.
  • Screens recycled plastics for contaminants.

Applications

  • Restricted substance screening of plastic parts
  • Filler element identification and verification
  • Brominated flame retardant checks
  • Recycled plastic contaminant screening

Specifications 技术参数

ParameterValue
Element range 元素范围 Na to U (light elements in vacuum)
Detector 检测器 Silicon drift detector, 25–50 mm²
Energy resolution 能量分辨率 About 130–150 eV at Mn Kα
Tube voltage 管电压 Up to 50 kV
Measurement spot 测量光斑 1–10 mm selectable
Detection limit 检出限 1–50 ppm depending on element
Measurement time 测量时间 60–300 s per sample
Atmosphere 测量气氛 Air, helium or vacuum
Power supply 电源 220 V, 50/60 Hz
Model No.PCA-0005
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 3451-1 ASTM D5630 ASTM D1603 ASTM E1131 ASTM D5576 ASTM D3452 ASTM F2617 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: X-Ray Fluorescence Analyzer for Plastic Elemental Analysis (PCA-0005)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

5 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.