Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

塑料组成分析仪

Plastic Composition Analysis

Model No. PCA-0004 · Plastic Analysis Equipment

FTIR Spectrometer for Plastic Composition Analysis

塑料组成分析用红外光谱仪

A failed part compared with a good reference, oxidation bands on an aged sample or filler peaks in a compound: this ATR-FTIR handles all of them. It scans 4000–400 cm⁻¹ at 1–4 cm⁻¹ with signal-to-noise better than 20,000:1. The library holds thousands of polymer and additive spectra.

Spectral range
4000–400 cm⁻¹
Resolution
1–4 cm⁻¹
Signal-to-noise ratio
Better than 20,000:1 at 4 cm⁻¹
ATR crystal
Diamond, single reflection
Sampling depth
About 2 µm at 1000 cm⁻¹
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

A failed part compared with a good reference, oxidation bands on an aged sample or filler peaks in a compound: this ATR-FTIR handles all of them. It scans 4000–400 cm⁻¹ at 1–4 cm⁻¹ with signal-to-noise better than 20,000:1. The library holds thousands of polymer and additive spectra.

Highlights

  • Single-reflection diamond ATR needs no preparation.
  • Sampling depth about 2 µm at 1000 cm⁻¹.
  • DLATGS detector with KBr window.
  • Desiccant or dry air purge.

Applications

  • Incoming polymer identification
  • Filler and additive band detection
  • Oxidative degradation assessment
  • Comparison of a failed part with a reference

Specifications 技术参数

ParameterValue
Spectral range 波数范围 4000–400 cm⁻¹
Resolution 分辨率 1–4 cm⁻¹
Signal-to-noise ratio 信噪比 Better than 20,000:1 at 4 cm⁻¹
ATR crystal ATR 晶体 Diamond, single reflection
Sampling depth 取样深度 About 2 µm at 1000 cm⁻¹
Detector 检测器 DLATGS with KBr window
Library capacity 谱库容量 Thousands of polymer and additive spectra
Purge requirement 吹扫要求 Desiccant or dry air purge
Power supply 电源 220 V, 50/60 Hz
Model No.PCA-0004
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 3451-1 ASTM D5630 ASTM D1603 ASTM E1131 ASTM D5576 ASTM D3452 ASTM F2617 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: FTIR Spectrometer for Plastic Composition Analysis (PCA-0004)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

5 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.