Ducted Class I Biosafety Cabinet管道式 I 级生物安全柜
- Cabinet class
- Class I
- Inflow velocity
- 0.7–1.0 m/s, monitored
II 级生物安全柜

Photo for reference; configuration may vary by order.
Model No. CLS-0002 · Biosafety Cabinets
II 级 B2 型生物安全柜
Protocols involving radioisotopes, hazardous drugs or toxic volatiles need a cabinet that recirculates nothing. Type B2 exhausts 100% of its air, 700–1600 m3/h, through a dedicated hard duct with a fan-to-cabinet interlock. Inflow is 0.38 to 0.51 m/s and filters are H14.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Protocols involving radioisotopes, hazardous drugs or toxic volatiles need a cabinet that recirculates nothing. Type B2 exhausts 100% of its air, 700–1600 m3/h, through a dedicated hard duct with a fan-to-cabinet interlock. Inflow is 0.38 to 0.51 m/s and filters are H14.
| Parameter | Value |
|---|---|
| Cabinet type 柜体类型 | Class II Type B2 |
| Inflow velocity 流入风速 | 0.38–0.51 m/s |
| Downflow velocity 下行风速 | 0.25–0.35 m/s |
| Recirculation 再循环 | 0 %, total exhaust |
| Total exhaust 总排风量 | 700–1600 m3/h |
| HEPA grade HEPA 等级 | H14 supply and exhaust |
| Duct connection 风管连接 | Dedicated, hard ducted |
| Interlock 互锁 | Fan to cabinet, standard |
| Width 宽度 | 900–1800 mm |
| Work surface 台面 | Stainless steel 304 |
| Model No. | CLS-0002 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.